Figure 9-9.  Item 820 Crimp Splice
Figure 9-13.  Item B23 Shielded Cable Splice

TM-1-1520-240-BD Army CH-47D Heilcopter (NSN 1520-01-088-3869) (EIC:RCD) Manual
Page Navigation
  133    134    135    136    137  138  139    140    141    142    143  
TM 1-1520-240-BD NOTE The item number on each illustration indicates   the   location   of   the   repair material    storage    container    and/or required     tools     within     the     wiring repair   kit   portion   of   the   ACM/BDR wiring repair set (see Figures 9-37, 9- 38, and 9-39). (2) Shielded   Primacy   Wire   Splicing.      The repair  set  provides  wire  splice  capability  for  24  to  12 AWG    shielded    cables    rated    at    125°C    or    above. Shielded TM 1-1520-240-BD primary wire repair should be accomplished using the techniques described in this paragraph.  Care should be exercised to stagger splices. Where  possible  splices  in  adjacent  wires  in  a  bundle should be separated by at least one splice length.  This may require the use of the pre-made splice segments or locally  manufactured  jumper  wires  made  from  the  kit primary  shielded  wire  stock.    Figures  9-11,  9-12,  9-13, and 9-14 illustrate the use of the pre-made shielded wire repair   segments   on   shielded   primary   wires   rated   at 1250C or above.  Adherence to the techniques will result in a permanent, environmentally-sealed shielded primary wire splice. Figure 9-11.  Item B21 Shielded Cable Splice 9-13