BEFORE LANDING - TM-1-1520-240-CL_13
BEFORE LEAVING HELICOPTER - TM-1-1520-240-CL_15

TM-1-1520-240-CL Army CH-47D Heilcopter (EIC:RCD) Manual
Page Navigation
  8    9    10    11    12  13  14    15    16    17    18  
TM 1-1520-240-CL N-11 F 8.   Mission equipment — Safe as required. O    9.   HUD — OFF. F 10.   Fire guard — Posted. L  11.   APU — Start. 12.   APU GEN switch — ON. 13.   GEN 1 and 2 switch — OFF (delay 2 seconds between 1 and 2). 14.   PWR XFER 1 and 2 switches — ON. 15.  Cyclic trim indicators — Check GND indication. 16.   ENG COND levers — GND, start 2 minute cool - down. F 17.    714A   DECU SHUTDOWN BIT — Check. 18.   FUEL CONTR switches — Set. F 19.    Droop stops — Engaged. 20.   ENG  COND  levers  —  STOP  after  2  minute cool-down. 21.  Avionics — OFF. FO 22.   Radar Altimeters — OFF. O  23.   EAPS Fan switches — OFF. F 24.   MAINTENANCE PANEL — Check. 25. 714A FADEC B/U PWR switch — OFF. 26.  PWR XFER 1 and 2 switches — OFF after rotors have stopped. 27.  APU GEN switch — OFF. 28.  APU switch — OFF. 29.  Light switches — OFF as required. 30.  BATT switch — OFF.