Electrical power is restored (from either generator)
LANDING AND DITCHING

TM-1-1520-240-CL Army CH-47D Heilcopter (EIC:RCD) Manual
Page Navigation
  21    22    23    24    25  26  27    28    29    30    31  
TM 1-1520-240-CL E-12 BATT SYS MAL Caution 1.  BATT CHGR circuit breaker — Out, then in. If the BATT SYS MAL caution remains on: 2.  BATT switch — OFF. HYDRAULIC NO. 1 or NO. 2 HYD FLT CONTR Caution Fluid loss is evident Land as soon as possible. Fluid loss is not evident 1.  PWR XFER 1 or 2 switch (affected system) — ON. F 2.  MAINTENANCE PANEL — Monitor. 3.  Land as soon as possible. High fluid temperature is evident. Land as soon as possible. NO. 1 and NO. 2 HYD FLT CONTR Caution 1.  PWR XFER 1 and 2 switches — ON. 2.  Land as soon as possible. UTIL HYD SYS Caution APU — Start. If pressure is restored: 1.  Land as soon as practicable. F 2.   MAINTENANCE PANEL — Monitor. If pressure is not restored: 1.  APU — Off. 2.  Land as soon as possible.