TM 1-1520-240-CL N-6 STARTING ENGINES *    1.   BATT switch — ON. 2.  CAUTION LT TEST switch — TEST. 3.  Clocks — Running. Set as required. F    4.   TROOP WARN ALARM and JUMP LTS — As required. F* 5.   Fire guard Posted — APU clear to start. L*   6.   APU — Start. *    7.   APU GEN switch — ON. F* 8.   PWR  XFER  1  and  2  switches  —  ON.  Check HYD FLT CONTR caution capsules out. F* 9.   MAINTENANCE PANEL — Check. * 10.   Avionics — ON as required.. O 11.   HUD — On as required. LF 12.   CARGO   HOOKS   HOIST/WINCH   —   Check operation as required. F 13.   ANTI-ICE system — Check as required. 14.  SLT-FIL switches — Check and set as required. * 15.   PARKING BRAKE — Set. 16.  CRUISE GUIDE indicator — Check. F* 17.   Altimeters — Set and check. 18.  FIRE DETR switch — TEST. * 19.   Fuel quantity — Check as required. * 20.   Cyclic trim indicators — Check GND position. F* 21.   Rotor blades — Check position. * 22.   AFCS SYSTEM SEL switch — Check. LF* 23.   Flight  control  travel  and  hydraulics  —  Check. Return to neutral. 24.  Avionics — Perform operational check and set as required.