Instrument Range Markings (Continued)
6.   TROOP ALARM and JUMP LIGHTS

TM-1-1520-240-MTF Army Model CH-47D Heilcopter (EIC:RCD) Manual
Page Navigation
  32    33    34    35    36  37  38    39    40    41    42  
TM 1-1520-240-MTF 2-33 BEFORE STARTING ENGINES (CONT.) B* 15.   VGI switches — NORM. B 16.   CYCLIC TRIM switch — AUTO. B* 17.   AFCS SYSTEM SEL switch — OFF. B* 18.   M-130 or AN/ALE-47 switch — SAFE/OFF. B 19.   Avionics equipment — Set as required. BO 20.   HEAD UP DISPLAY — HUD Off. B 21.    712   EMERG ENG TRIM switches — AUTO, covers down. B 22.   Swivel switch - Lock. STARTING ENGINES 1-9. 1.  Personal equipment — Check. B*    2.   BATT  switch  —  ON.  Check  BAT  SYS  MAL caution light out (may stay on until APU GEN is on if SLAB installed) and the following caution panel lights on: XMSN OIL PRESS, L. FUEL PRESS, R. FUEL PRESS, XMSN AUX OIL PRESS, NO. 1 RECT OFF, NO. 2 RECT OFF, NO. 1 GEN OFF, NO. 2 GEN OFF, NO. 1 HYD FLT CONTR, NO. 2 HYD FLT CONTR, UTIL HYD SYS, NO 1 AFCS OFF, NO. 2 AFCS OFF,   714A   FADEC 1, FADEC 2. 3.  Interphone — Check stations. B 4.   MASTER  CAUTION  LIGHTS  TEST  switch  — TEST.   Check   that   all    712     caution    714A caution/advisory capsules and the two MASTER CAUTION lights on the instrument panel come on. B 5.   Clocks — check operation, set as required.