8.21 Utility hydraulic pump and hoses for leaks
8.36 Hydraulic fill module for leaks and security

TM-55-1520-240-PM CH-47D Heilcopter Manual
Page Navigation
  68    69    70    71    72  73  74    75    76    77    78  
TM 55-1520-240-PM PHASE NO. _____ Area Name and No. Aircraft Serial No. Date RAMP AREA #8 Inspect Phase No’s Inspection Requirements Status Faults and/or Remarks Action Taken Initial ALL 8.27 Troop alarm arm bell and lights for condition and security. ALL 8.28 Utility hydraulic return module housing, mount structure, and transfer cylinder for leakage, cracks, buckling, and damage. ALL/C 8.29 Flight control links and bellcranks throughout the aft cabin area for security, damage, and corrosion. Connecting link swaged inserts for evidence of looseness. ALL 8.30 Fire bottles for pressure and wire connectors. System tubing for security and condition. ALL/C 8.31 Bellcrank supports at STA 534.00 (left and right) and adjacent structure for security, corrosion, and cracks. ALL 8.32 Fuel and crossfeed valves and hoses for condition and security. ALL 8.33 Inspect P3 drain cartridge plastic tube (LH and RH) for cracks, security, and broken or missing hardware. (With  74 ) "FOD REMINDER" Check work area for tools and parts after completion of maintenance and inspection. 2-61