NO. 1 ENGINE GROUND IDLE SPEED BELOW 60 TO 63 PERCENT RPM (Continued) 4-1.3 63 PERCENT RPM (Continued)
NO.  2  ENGINE  HIGH  PTIT  READING  DURING  START  OR HOT  START  (Continued) - TM-55-1520-240-T-1_236

TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
  192    193    194    195    196  197  198    199    200    201    202  
TM 55-1520-240-T 4-1.4 NO. 2 ENGINE HIGH  PTIT READING DURING START OR HOT START 4-1.4 FAULT ISOLATION PROCEDURE INITIAL SETUP References: Applicable Configurations: TM 55-1520-240-10 Without 74 TM 55-1520-240-23 Tools. TM 55-2840-254-23 Tools: Powerplant Repairer's Tool Kit, Equipment Condition: NSN 5180-00-323-4944 TM 55-1520-240-23: Materials: Battery Connected None Electrical Power On Personnel Required: Hydraulic Power On Aircraft Powerplant Repairer Rotary wing Aviator (2) GO TO NEXT PAGE 4-12  Change 17