NO. 1 ENGINE ANTI-ICING VALVE DOES NOT OPERATE 4-2.6 (CLICK NOT HEARD) (Continued)
NO.   2   ENGINE   ANTI-ICING   VALVE   DOES   NOT   OPERATE (CLICK   NOT   HEARD)   (Continued)

TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
  218    219    220    221    222  223  224    225    226    227    228  
TM 55-1520-240-T 4-2.7 NO. 2 ENGINE ANTI-ICING VALVE DOES NOT OPERATE (CLICK NOT HEARD) 4-2.7 FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required: Applicable Configurations: Aircraft Electrician Without 43 and 74 References: Tools: TM 55-1520-240-23 Electrical Repairer's Tool Kit, Equipment Condition: NSN 5180-00-323-4915 TM 55-1520-240-23: Multimeter Battery Disconnected Materials: Electrical Power On None Hydraulic Power Off GO TO NEXT PAGE 4-40  Change 17