NO.   1   ENGINE   FUEL   CONTROL   POINTER   DOES   NOT   MOVE OR   MOVES   BUT   STOPS   OUTSIDE   OF   13   TO   21 ON   PROTRACTOR   (DECREASE   SELECTED)   (Continued)
NO.   1   ENGINE   FUEL   CONTROL   POINTER   DOES   NOT   MOVE OR   MOVES   BUT   STOPS   OUTSIDE   OF   13   TO   21 ON   PROTRACTOR   (DECREASE   SELECTED)   (Continued)

TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
  325    326    327    328    329  330  331    332    333    334    335  
TM    55-1520-240-T 4-6.11   NO.   1   ENGINE   FUEL   CONTROL   POINTER   DOES   NOT   MOVE OR   MOVES   BUT   STOPS   OUTSIDE   OF   13°   TO   21° ON   PROTRACTOR   (DECREASE   SELECTED)   (Continued) 4-6.11 HOLD   PILOTS   NO.   1   AND   NO. 2   TRIM   SWITCH   AT   DEC   OPEN RIGHT     ELECTRICAL     COMPART-. MENT    CHECK    FOR    28    VDC BETWEEN   RELAY   103K2   TERM A2(+)    AND    GROUND    1S28 VDC   PRESENT? CHECK   FOR   28   VDC   BETWEEN RELAY   103K2   TERM   A1   (   +   ) AND   GROUND   IS   28   VDC PRESENT/ C HECK  FOR   GROUND   ON RELAY   103K2   TERM   X 2   IS GROUND    PRESENT? YES HOLD   PILOT’S   NO.   1   AND   NO. 2   TRIM   SWAT   DEC.   CHECK FOR   28   VDC   BETWEEN   RELAY 103K2   TERMX1   (+)   AND GROUND   IS   28   VDC   PRESENT? LOCATE   OPEN   IN   WIRE   W592 52-22    BETWEEN    RELAY    103K2 AND   RELAY   103K1   REPAIR   OR REPLACE    WIRE    AS    REQUIRED REPLACE   RELAY   103K2 RELEASE    SW    DISCONNECT ELECTRICAL   POWER DISCONNECT    PLUG    103P1 FROM    CONTROL    BOX.    CHECK FOR   CONTINUITY   BETWEEN PLUG    103P1    PIN    8    AND    RELAY 103K2     TERM     A2 IS CONTINUITY    PRESENT? LOCATE   OPEN   IN   WIRE   W591- 67-22    BETWEEN    PLUG    103P1 AND   RELAY   103K2   REPAIR   OR REPLACE    WIRE    AS    REQUIRED LOCATE    OPEN    IN    WIRE    W591- GD132F20    BETWEEN    RELAY 103K1   AN   D   GROUND   MODULE GD173   REPAIR   OR   REPLACE OPEN    LEFT    ELECTRICAL    COM- PARTMENT    CHECK    FOR GROUND   ON   RELAY   103K1 TERM   A3   IS   GROUND PRESENT? CHECK   FOR   GROUND   ON   PLUG 103P1   PINA   IS   GROUND PRESENT? LOCATE    OPEN    IN    WIRE    W591- 2522    BETWEEN    PLUG    103P1 AND   RELAY   1O3K1   REPAIR   OR REPLACE    WIRE    AS    REQUIRED CHECK    FOR    CONTINUITY BETWEEN    PLUG    103P1    PIN    A AN   ORE   LAY   103K1   TERM   A2   IS CONTINUITY    PRESENT? REPLACE   NO   1   CONTROL   BOX REPLACE   RELAY   103K1 GO  TO  NEXT  PAGE 4-152 Change 1







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.