NO.   1   ENGINE   FUEL   CONTROL   POINTER   DOES   NOT   MOVE OR   MOVES   BUT   STOPS   OUTSIDE   OF   13   TO   21 ON   PROTRACTOR   (DECREASE   SELECTED)   (Continued)
NO.   2   ENGINE   POWER   TURBINE   LEVER   DOES   NOT   MOVE OR   MOVES   BUT   DOES   NOT   CONTACT   STOP   (INCREASE SELECTED)   (Continued)

TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
  327    328    329    330    331  332  333    334    335    336    337  
TM 55-1520-240-T 4-6.12    NO. 2 ENGINE POWER TURBINE LEVER DOES NOT MOVE OR MOVES BUT DOES NOT CONTACT STOP (INCREASE SELECTED) 4-6.12 FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required: Applicable Configurations: Medium Helicopter Repairer Without 74 Aircraft Electrician Tools: References: Electrical Repairer's Tool Kit, TM 55-1520-240-23 NSN 5180-00-323-4915 Equipment Condition: Aircraft Mechanic's Tool Kit, TM 55-1520-240-23 NSN 5180-00-323-4692 Battery Connected Multimeter Electrical Power On Materials: Hydraulic Power Off None GO TO NEXT PAGE 4-154  Change 17