NO. 1 ENGINE FUEL CONTROL POINTER DOES NOT MOVE 4-6.19 WHEN EMERGENCY ENGINE TRIM 1 SWITCH SET TO DEC. (Continued)
NO. 2 ENGINE FUEL CONTROL POINTER DOES NOT MOVE 4-6.20 WHEN EMERGENCY ENGINE TRIM 2 SWITCH SET TO INC. (Continued)

TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
  347    348    349    350    351  352  353    354    355    356    357  
TM 55-1520-240-T 4-6.20 NO. 2 ENGINE FUEL CONTROL POINTER DOES NOT MOVE WHEN EMERGENCY ENGINE TRIM I SWITCH SET TO INC 4-6.20 FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required: Applicable Configurations: Medium Helicopter Repairer Without 74 Aircraft Electrician Tools: References: Aircraft Mechanic's Tool Kit, TM 55-1520-240-23 NSN 5180-00-323-4692 Equipment Condition: Electrical Repairer's Tool Kit, TM 55-1520-240-23: NSN 5180-00-323-4915 Battery Connected Multimeter Electrical Power On Materials: Hydraulic Power Off None GO TO NEXT PAGE 4-172  Change 17