DECU CODE B4 OR E1 (Continued)
4-12.21  DECU CODE E3

TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
  453    454    455    456    457  458  459    460    461    462    463  
TM 1-2840-265-23 TM 1-2840-265-23 TM 1-2840-265-23 TM 1-2840-265-23 TM 55-1520-240-T 4-12.20  DECU CODE E2 4-12.20 FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required: Applicable Configurations: Aircraft Electrician With 74 Aircraft Powerplant Repairer Tools: References: Electrical Repairer's Tool Kit, TM 1-2840-265-23 NSN 5180-00-323-4915 TM 55-1520-240-23 Powerplant Repairer's Tool Kit, NSN 5180-00-323-4944 Equipment Condition: Multimeter TM 55-1520-240-23: Battery Disconnected Materials: Electrical Power Off None Hydraulic Power Off NOTE: Information in ( ) applies to DECU NO. 2. END OF TASK 4-290  Change 17