6-2.17   LEFT   COMB   TRANSMISSION   DEBRIS   SCREEN   INDICATOR   DOES   NOT   CHANGE   TO   BLACK-AND- 6-2.17 WHITE   FAN   DISPLAY   WHEN   DEBRIS   SCREEN   SHORTED
6-2.19    RIGHT TRANSMISSION DEBRIS SCREEN INDICATOR DOES 6-2.19 NOT CHANGE TO BLACK-AND-WHITE FAN DISPLAY WHEN DEBRIS SCREEN SHORTED

TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
  576    577    578    579    580  581  582    583    584    585    586  
TM   55-1520-240-T 6-2.18   LEFT   TRANSMISSION   DEBRIS   SCREEN   INDICATOR DOES   NOT   CHANGE   TO   BLACK-AND-WHITE   FAN   DISPLAY WHEN   DEBRIS   SCREEN   SHORTED FAULT   ISOLATION   PROCEDURE INITIAL   SETUP Applicable     Configurations: All Tools: Electrical  Repairer’s  Tool  Kit, NSN   5180-00-323-4915 Multi  meter Materials: None Personnel   Required: 6 7 U 1 0     M e d i u m     H e l i c o p t e r     R e p a i r er 68F20    Aircraft    Electrician References: T M     5 5 - 1 5 2 0 - 2 4 0 - 23 Equipment  Condition: T M    5 5 - 1 5 2 0 - 2 4 0 - 2 3: Battery    Connected Electrical   Power   On Hydraulic   Power   Off 6-2.18 END  OF  TASK 6-76