TM 55-1520-240-T7-1.4 FLIGHT CONTROL HYDRAULIC SYSTEM OPERATIONAL CHECK (Continued)7-1.4TASKRESULT11.Checkthat FLT CONTR switch (14)is at BOTH.If not, set switch (14) to BOTH.12Set POWER XFR NO. 1 AND NO. 2 switches (1 and 2).NO. 1 HYD FLT CONTR (Without 74 ) HYD 1 (With 74 )to ON.and NO. 2 HYD FLT CONTR (Without 74 ) HYD 2 (With74) capsules (12 and 13) shall go out. If either capsuleis still on, go to Task 7-12.15.13Check maintenance panel (15).FLT CONT NO. 1 and FLT CONT NO. 2 HYDRAULICSPRESS indicators (16 and 17) shall indicate 2500to3000psiand pointers shall fluctuate more than 100psi. Ifeither does not indicate more than 2500to3000psi orpointer fluctuates more than 100psi go to Task 8-7.3.If either pointer fluctuates from 1800to2200psi, replacecheck valve on No. 1 or No. 2 power control modulebefore replacing any module.Pointers on FLT CONT NO. 1 and FLT CONT NO. 2HYDRAULICS TEMPERATURE indicators (18 and 19)shall move upscale as fluid temperature increases. Tem-perature indication shall not exceed 95C. If either pointerdoes not move, go to Task 8-8.3 If either pointer exceeds95C, go to Task 7-1.15 or 7-1.16.FLT CONT NO. 1 PRESS and RTN FILTER CHANGElights (20) shall be out. If either light is on, go to Task7-1.17.FLT CONT NO. 2 PRESS and RTN FILTER CHANGElights (21) shall be out. If either light is on, go to Task7-1.18.14.Slowly move pilot pitch and roll control and thrustControl and lever (22 and 23) travel shall be smooth andlever (22 and 23) through their travel range for 5without binding or restriction. All hoses to flight controlminutes. Check all flight control hydraulic systemhydraulic system parts shall not be pinched, chaffed orcomponents for leaks and ease of movement.stretched during control and lever movement. Hydraulicfluid leakage shall not exceed limits noted inTM 55-1520-240-23. If any binding or restriction is noted,locate cause and re-position or replace binding or restrictedpart. Re-position hose if it is being pinched, chaffed, orstretched. Tighten or replace leaking parts as required.TASKRESULT15.Check two jam sensors on each actuator (24, 25, 26, If any sensor (28) is extended, go to Task 7-1.5.and 27).16.Check jam sensor on each actuator (29, 30, 31, andIf any jam sensor button (33) is extended, go to Task32).7-1.19.17.Repeat step 13, then go to step 18.18.Set FLT CONTR switch (14) to NO. 1 ON.NO. 2 HYD FLT CONT (Without 74 ) capsule (13) shallcome on. HYD 2 (With 74 ) capsule (13) shall come on.If capsule does not come on, go to Task 7-1.20.19.Set FLT CONTR switch (14) to NO. 2 ON.NO. 2 HYD FLT CONT (Without 74 ) capsule (13) shallgo out. HYD 2 (With 74 ) capsule (13) shall go out. NONO. 1 HYD FLT CONT (Without 74 ) capsule (12) shallcome on. HYD 1 (With 74 ) capsule (12) shall come on.If capsule (12) does not come on, go to Task 7-1.21.GO TO NEXT PAGE7-16 Change 17
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business