NO. 1 HYD FLT CONTR (WITHOUT  74 ) OR HYD 1 (WITH  74) CAPSULE DOES NOT COME ON WHEN FLIGHT CONTROL SWITCH SET TO NO. 2 ON (Continued)
NO. 1 HYD FLT CONTR (WITHOUT  74 ) HYD 1 (WITH  74) CAPSULE COMES ON WHEN NO. 2 SYSTEM IS SELECTED AND DEPRESSURIZED

TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
  652    653    654    655    656  657  658    659    660    661    662  
TM 55-1520-240-T 7-1.22    NO. 2 HYD FLT CONTR (WITHOUT  74 ) HYD 2 (WITH  74) CAPSULE COMES ON WHEN NO. 1 SYSTEM DEPRESSURIZED THEN SELECTED 7-1.22 FAULT ISOLATION PROCEDURE INITIAL SETUP References: TM 55-1520-240-23 Applicable Configurations: All Equipment Condition: TM 55-1520-240-23: Tools: Battery Disconnected Electrical Repairer's Tool Kit Electrical Power Off NSN 5180-00-323-4915 Hydraulic Power Off Multimeter Materials: None Personnel Required: Medium Helicopter Repairer Aircraft Electrician LOCATE GROUND FAULT ON WIRE W639-24-20,     W645-14-22,     W697-117-22, W668-116-22    OR    W528-8-20    BETWEEN NO.     1     SYSTEM     PRESSURE     SWITCH PLUG  033P1  AND  NO.  2  SYSTEM  PILOT VALVE     PLUG     G033P2.          REPAIR     OR REPLACE WIRE AS REQUIRED. END OF TASK 7-66  Change 17