  664    665    666    667    668  669  670    671    672    673    674  
TM 55-1520-240-T 7-2.3  UTILITY HYDRAULIC SYSTEM VISUAL CHECK (Continued) 7-2.3 TASK RESULT 14.  Check No. 2 power transfer unit (17). If No. 2 PTU (17) is loose or damaged, tighten or replace it as required.  If any hose or tube-to-No-2 PTU is loose or damaged.  tighten or replace it as required.  If any electrical connector to PTU is loose or damaged, tighten or replace it as re- quired.  If wiring to connector is damaged, repair or replace it as required. 15.  Check No. 1 power transfer unit (18). If No. 1 PTU (1 8) is loose or damaged, tighten or replace it as required.  If any hose or tube to No. 1 PTU is loose or damaged, tighten or replace it as required.  If any electrical connector to PTU is loose or damaged.  tighten or replace it as re- quired.  If wiring to connector is damaged, repair or replace it as required. FOLLOW-ON MAINTENANCE: TM 55-1520-240-23: Pylon Access Doors Closed Right Forward Work platform Closed END OF TASK 7-79