  760    761    762    763    764  765  766    767    768    769    770  
TM    55-1520-240-T 7-5.6   AFT   RIGHT   WHEEL   DOES   NOT   RETURN   TO   NEUTRAL FAULT   ISOLATION   PROCEDURE INITIAL   SETUP Applicable  Configurations: All Tools: Electrical   Repairer’s   Tool   Kit, N S N     5 1 8 0 - 0 0 - 3 2 3 - 4 9 15 Multi    meter Materials: None Personnel    Required: 68F10    Aircraft    Electrician 68F20    Aircraft    Electrician References: T M     5 5 - 1 5 2 0 - 2 4 0 - 23 Equipment  Condition: T M    5 5 - 1 5 2 0 - 2 4 0 - 2 3: Battery     Disconnected Electrical   Power   Off Hydraulic   Power   Off 7-5.6 D145-11475-SPA GO  TO  NEXT  PAGE 7 - 1 6 8