APU  HYDRAULIC  STARTING  SYSTEM  OPERATIONAL  CHECK
APU  START  ACCUMULATOR  GAGE  DOES  NOT  INDICATE  AT  LEAST 3000   PSI   (Continued)

TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
  799    800    801    802    803  804  805    806    807    808    809  
TM   55-1520-240-T 7-8.4  APU  START  ACCUMULATOR  GAGE  DOES  NOT  INDICATE  AT  LEAST 3000   PSl 7-8.4 FAULT  ISOLATION  PROCEDURE INITIAL   SETUP Personnel Required: Medium   Helicopter   Repairer   (2) Applicable Configurations: All References: TM   55-1520-240-23 Tools: Aircraft   Mechanic’s   Tool   Kit, NSN   5180-00-323-4692 Hydraulic   Power   Source Pressure  Gage  5000  PSI Equipment Condition: TM   55-1520-240-23: Battery   Connected Electrical  Power  On Hydraulic   Power   Off Materials: None GO TO NEXT PAGE Page 7-213 is a blank page. Change 1 7-214