INTEGRATED  LOWER  CONTROL  ACTUATOR  (ILCA) FAILS TEST 10 (PROOF PRESSURE TEST (ALL))
INTEGRATED  LOWER  CONTROL  ACTUATOR  (ILCA) FAILS TEST 14 (RELIEF VALVE TEST (ALL))

TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
  814    815    816    817    818  819  820    821    822    823    824  
TM   55-1520-240-T 7-9.10  INTEGRATED  LOWER  CONTROL  ACTUATOR  (ILCA) FAILS TEST 12 VALVE JAM INDICATOR TEST (ALL)) 7.9.10 FAULT  ISOLATION  PROCEDURE INITIAL   SETUP Applicable Configurations: All Tools: Aircraft   Mechanic’s   Tool   Kit, NSN   5180-00-323-4692 Multimeter Materials: None Personnel Required: 68H20   Aircraft   Pneudraulic   Repairer References: TM   55-1520-240-23 Equipment Condition: Visual  Check  of  Integrated  Lower  Control  Ac- tuator  (ILCA)  Performed  (Task  7-9.2) REPLACE   JAM   INDICATOR THAT   FAILED   TEST. REPEAT    TEST    DOES    lNDlCA- TOR   PASS   TEST? FORWARD    ILCA    TO    DEPOT FOR   DISPOSITION. FAULT     CORRECTED 45 x 54 D145-12468-SPA END  OF  TASK 7-231