HYDRAULIC   HANDPUMP   FAILS   PRESSURE   ADJUSTMENT TEST  (Continued)
HYDRAULIC  HANDPUMP  FAILS  FLUID  DISPLACEMENT  TEST

TM-55-1520-240-T-1 CH-47D Heilcopter Manual
Page Navigation
  822    823    824    825    826  827  828  
TM   55-1520-240-T 7-10.4 HYDRAULIC  HANDPUMP  FAILS  HANDLE  FORCE  TEST FAULT ISOLATION PROCEDURE INITIAL   SETUP Applicable   Configurations: All Tools: Hydraulic   Repairer’s   Tool   Kit, NSN   5180-00-323-4891 Materials: None Personnel   Required: 68H20   Aircraft   Pneudraulics   Repairer References: TM   55-1520-240-23 Equipment Condition: TM    55-1520-240-23: Hydraulic   Handpump   in   AVIM   Test   Setup General Safety Instructions: Hydraulic  fluid  ejected  under  pressure  can cause   injury   to   personnel.   Hydraulic   fluid sprayed  into  the  air  is  a  fire  hazard. 7-10.4 45 x 54 D145-12663-SPA END   OF   TASK 7-242