  166    167    168    169    170  171  172    173    174    175    176  
TM 55-1520-240-T 8-6.9 NO. 2 POINTER ON PILOTS OR COPILOTS TORQUE INDICATOR DOES NOT INDICATE PROPER TORQUE USING TORQUE SIGNAL SIMULATOR 8-6.9 FAULT ISOLATION PROCEDURE Personnel Required: Aircraft Electrician (2) INITIAL SETUP Applicable Configurations: References: With 74 TM 55-1520-240-23 Tools: Equipment Condition: Electrical Repairer Tool Kit, TM 55-152024023: NSN 5180-00-323-4915 Battery Connected Materials: Electrical Power On None Hydraulic Power On GO TO NEXT PAGE 8-120.2  Change 19