F W D ,   C O M B ,   A F T ,   A F T   S H A F T ,   L E F T ,   O R   R I G H T   T R A N S M I S S I O N   M A I N   O I L   P R E S S   L I G H T   D O E S   N OT C O M E   O N   W H E N   P R E S S E D   ( C o n t i n u e d)
X M S N    O I L    P R E S S    C I R C U I T    B R E A K E R    D O E S    N O T    S T A Y    C L O S E D ( C o n t i n u e d )

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  242    243    244    245    246  247  248    249    250    251    252  
8-9.16 TM   55-1520-240-T 8-9.16   XMSN   OIL   PRESS   CIRCUIT   BREAKER   DOES   NOT   STAY   CLOSED FAULT   ISOLATION   PROCEDURE INITIAL   SETUP Applicable    Configurations: All Tools: Electrical  Repairer’s  Tool  Kit, NSN   5180-00-323-4915 Multimeter Materials None Personnel   Required: 68F20   Aircraft   Electrician 68F20   Aircraft   Electrician References: TM   55-1520-240-23 Equipment   Condition: TM   55-1520-240-23: Battery    Connected Electrical  Power  On Hydraulic   Power   Off G O    T O    N E X T    P A GE 8  -  2  0  2