XMSN OIL HOT CAPSULE LIT AFT TRANSMISSION OVERTEMP INDICATOR IS DURING TEST (Continued)
XMSN OIL HOT CAPSULE LIT OR COMB TRANSMISSION OVERTEMP INDICATOR IS BLACK DURING TEST (Continued)

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  293    294    295    296    297  298  299    300    301    302    303  
TM 55-1520-240-T 8-10.13 XMSN OIL HOT CAPSULE LIT OR COMB TRANSMISSION OVERTEMP INDICATOR IS BLACK DURING TEST 8-10.13 FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required: Applicable Configurations: Aircraft Electrician All References: Tools: TM 55-1520-240-23 Electrical Repairer's Tool Kit, Equipment Condition: NSN 5180-00-3234915 TM 55-1520-240-23: Multimeter Battery Connected Materials: Electrical Power On None Hydraulic Power Off GO TO NEXT PAGE 8-248  Change 19