FUEL QTY AC CIRCUIT BREAKER WILL NOT STAY CLOSED
F U E L    Q U A N T I T Y    I N D I C A T I O N    W R O N G    W H E N    F U E L    Q U A N T I TY SELECT   SWITCH   IS   SET   TO   L   MAIN   (Continued)

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  315    316    317    318    319  320  321    322    323    324    325  
TM 55-1520-240-T 8-11.6 FUEL QUANTITY INDICATION WRONG WHEN FUEL QUANTITY SELECT SWITCH IS SET TO L MAIN 8-11.6 FAULT ISOLATION PROCEDURE INITIAL SETUP References: Applicable Configurations: TM 55-1520-240-23 All Equipment Condition: Tools: TM 55-1520-240-23: Electrical Repairer Tool Kit, Battery Connected NSN 5180-00-323-4915 Electrical Power On Multimeter Hydraulic Power Off Materials: Right Fwd Landing Gear Access Panel Open None Personnel Required: Aircraft Electrician (2) GO TO NEXT PAGE 8-270  Change 19