FUEL QUANTITY INDICATOR POINTER SPINS CONTINUOUSLY WHEN FUEL QUANTITY SELECT SWITCH IS SET TO ANY POSITION (Continued)
FUEL QUANTITY INDICATION WRONG WHEN FUEL QUANTITY SELECT SWITCH IS SET TO L FWD 8-11.8 (Continued)

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  321    322    323    324    325  326  327    328    329    330    331  
TM 55-1520-240-T 8-11.8    FUEL QUANTITY INDICATION WRONG WHEN FUEL QUANTITY SELECT SWITCH IS SET TO L FWD 8-11.8 FAULT ISOLATION PROCEDURE INITIAL SETUP References: Applicable Configurations: TM 55-1520-240-23 All Equipment Condition: Tools: TM 55-1520-240-23: Electrical Repairer Tool Kit, Battery Connected NSN 5180-00-323-4915 Electrical Power On Multimeter Hydraulic Power Off Materials: Right Forward Landing Gear Access Panel Open None Personnel Required: Aircraft Electrician (2) GO TO NEXT PAGE 8-276  Change 19