R FUEL LOW (WITHOUT  74), R FUEL LVL (WITH 74), WARNING CAPSULE DOES NOT COME ON WHEN RIGHT MAIN TANK FUEL LEVEL IS BELOW 320 TO 420 POUNDS
REFUEL PANEL FUEL QUANTITY INDICATOR DOES NOT 8-11.18 INDICATE FUEL LEVEL AT ANY SWITCH POSITION (Continued)

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  338    339    340    341    342  343  344    345    346    347    348  
TM 55-1520-240-T 8-11.18 REFUEL PANEL FUEL QUANTITY INDICATOR DOES NOT INDICATE FUEL LEVEL AT ANY SWITCH POSITION 8-11.18 FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required: Applicable Configurations: Aircraft Electrician All References: Tools: TM 55-1520-240-23 Electrical Repairer Tool Kit, Equipment Condition: NSN 5180-00-323-4915 TM 55-1520-240-23: Multimeter Battery Connected Materials: Electrical Power On None Hydraulic Power Off GO TO NEXT PAGE 8-294  Change 19