MAINTENANCE   PANEL   POWER   DISTRIBUTION   WIRING   DIAGRAM
MAINTENANCE   PANEL   POWER   DISTRIBUTION   OPERATIONAL   CHECK

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  361    362    363    364    365  366  367    368    369    370    371  
TM   55-1520-240-T 8-14.2   MAINTENANCE   PANEL   POWER   DISTRIBUTION   VISUAL   CHECK 8-14.2 INITIAL   SETUP Personnel   Required: Applicable Configurations: Aircraft    Electrician All References: Tools: TM    55-1520-240-23 Electrical   Repairer’s   Tool   Kit, Equipment   Condition: NSN     5180-00-323-4915 TM    55-1520-240-23 Materials: Battery     Disconnected None Electrical   Power   Off Hydraulic   Power   Off TASK RESULT 1 2 3 Check   maintenance   panel   light   (1)   and If   light   (1)   is   damaged,   replace   it.   If   cord   (2)   is   dam- cord   (2). Check   electrical   connectors aged,  replace  light. (3   and   4). If   either   connector   (3   or   4)   is   loose   or   damaged, tighten   or   replace   it   as   required.   If   wires   to   either connector   are   damaged,   repair   or   replace   them   as required. W i t h       ,    c h e c k    l e f t    a n d    r i g h t    G R O U ND If   either   light   (5   or   6)   is   loose   or   damaged,   tighten   or CONTACT   lights   (5   and   6). replace   it   as   required. FOLLOW-ON     MAINTENANCE: None END OF TASK 8-321