• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
DC POWER SYSTEM OPERATIONAL CHECK (Continued) - TM-55-1520-240-T-2_520
MASTER CAUTION LIGHTS DO NOT COME ON WHEN BATTERY SWITCH SET TO ON (Continued)

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  441    442    443    444    445  446  447    448    449    450    451  
TM 55-1520-240-T 9-1.5 MASTER CAUTION LIGHT DO NOT COME ON WHEN BATTERY SWITCH SET ON 9-1.5 FAULT ISOLATION PROCEDURE INITIAL SETUP Reference: Applicable Configurations: TM 55-1520-240-23 All Equipment Condition: Tools: TM 55-1520-240-23: Electrical Repairer Tool Kit, Battery Connected NSN 5180-00-323-4915 Electrical Power On Multimeter Hydraulic Power Off Materials: None Personnel Required: Medium Helicopter Repairer Aircraft Electrician GO TO NEXT PAGE 9-14  Change 6