CABIN  AND  RAMP  LIGHTS  NOT  POWERED  FROM SWITCHED  BATTERY  BUS
NO. 1 AND NO. 2 RECT OFF (WITHOUT 74) RECT 1 AND RECT 2 (WITH 74)CAPSULE OUT WHEN EXTERNAL DC SUPPLY CONNECTED (Continued)

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  473    474    475    476    477  478  479    480    481    482    483  
TM 55-1520-240-T 9-1.17    NO. 1 AND NO. 2 RECT OFF (WITHOUT 74) RECT 1 AND RECT 2 (WITH 74) CAPSULE OUT WHEN EXTERNAL DC SUPPLY CONNECTED 9-1.17 FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required: Applicable Configurations: Medium Helicopter Repairer All Aircraft Electrician Tools: References: Electrical Repairer's Tool Kit, TM 55-1520-240-23 NSN 5180-00-323-4915 Equipment Condition: Aircraft Mechanic's Tool Kit TM 55-1520-240-23: NSN 5180-00-323-4692 Battery Connected Multimeter Electrical Power On Materials: Hydraulic Power Off None GO-TO NEXT PAGE 9-46  Change 19  Page 9-45 is a blank page.