AC POWER SYSTEM OPERATIONAL CHECK (Continued) - TM-55-1520-240-T-2_578
NO. 1 AND NO. 2 RECT OFF (WITHOUT 74) OR RECT 1 AND RECT 2 (WITH  74) CAUTION LIGHTS ON - TM-55-1520-240-T-2_580

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  496    497    498    499    500  501  502    503    504    505    506  
TM 55-1520-240-T 9-2.5 NO. 1 AND NO. 2 RECT OFF (WITHOUT 74) OR RECT 1 AND RECT 2 (WITH  74) CAUTION LIGHTS ON 9-2.5 FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required: Applicable Configurations: Aircraft Electrician (2) All References: Tools: TM 55-1520-240-23 Electrical Repairer's Tool Kit, Equipment Condition: NSN 5180-00-323-4915 TM 55-1520-240-23: Multimeter Battery Connected Materials: Electrical Power On None Hydraulic Power Off 9-68  Change 19  Page 9-67 is a blank page. GO TO NEXT PAGE