• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
NO. 2 GEN OFF CAPSULE (WITHOUT 74) OR GEN 2 CAPSULE (WITH 74) STAYS ON (GENERATOR SWITCH IN TEST) (Continued) - TM-55-1520-240-T-2_602
NO. 2 GENERATOR OFF (WITHOUT 74) GEN 2 (WITH  74) CAPSULE IS ON (GENERATOR SWITCH ON) - TM-55-1520-240-T-2_604

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  520    521    522    523    524  525  526    527    528    529    530  
TM 55-1520-240-T 9-2.11    NO. 2 GENERATOR OFF (WITHOUT 74) GEN 2 (WITH  74) CAPSULE IS ON (GENERATOR SWITCH ON) 9-2.11 FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required: Applicable Configurations: Aircraft Electrician All References: Tools: TM 55-1520-240-23 Electrical Repairer's Tool Kit, Equipment Condition: NSN 5180-00-323-4915 TM 55-1520-240-23: Multimeter Battery Connected Materials: Electrical Power On None Hydraulic Power Off GO TO NEXT PAGE 9-88  Change 19