OIL LEVEL CHECK CIRCUIT BREAKER DOES NOT STAY CLOSED
PILOTS FLIGHT INSTRUMENT PANEL LIGHTS WIRING DIAGRAM - TM-55-1520-240-T-2_704

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  606    607    608    609    610  611  612    613    614    615    616  
TM  55-1520-240-T 9-7.5   FORWARD   TRANSMISSION   OIL   LEVEL   CHECK   LIGHT   NOT   LIT FAULT    ISOLATION    PROCEDURE Personnel    Required: 68F20    Aircraft    Electrician INITIAL   SETUP References: T M     5 5 - 1 5 2 0 - 2 4 0 - 23 Applicable Configurations: All Equipment   Condition: T M    5 5 - 1 5 2 0 - 2 4 0 - 2 3: Battery    Connected Electrical   Power   On Hydraulic   Power   Off Tools: Electrical   Repairer’s   Tool   Kit, N S N     5 1 8 0 - 0 0 - 3 2 3 - 4 9 15 Multimeter Materials: None 9-165/(9-166 blank)