• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
 CONSOLE PANEL LIGHT OR LIGHTS NOT LIT  (Continued)
LONGITUDINAL STICK POSITION INDICATOR NOT LIT - TM-55-1520-240-T-2_815

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  705    706    707    708    709  710  711    712    713    714    715  
9-12.12 LONGITUDINAL STICK POSITION INDICATOR NOT LIT 9-12.12 FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required Aircraft Electrician Applicable Configurations: References: With17 TM 55-1520-240-23 Tools: Electrical Repairer’s Tool Kit, Equipment Condition: NSN 5180-00-323-4915 TM 55-1520-240-23: Multimeter Battery Connected Electrical Power On Materials: Hydraulic Power Off None TM 55-1520-240-T 9-12.12 GO  TO  NEXT PAGE Change 15  9-228.15