TM   55-1520-240-T 9-15.4   CABIN   &   RAMP   CIRCUIT   BREAKER   DOES   NOT   STAY   CLOSED 9 - 1 5 . 4 FAULT   ISOLATION   PROCEDURE INITIAL  SETUP Applicable    Configurations: Tools: Electrical  Repairer’s  Tool  Kit, NSN   5180-00-323-4915 Multimeter Materials: None References: TM   55-1520-240-23 Equipment    Condition: TM   55-1520-240-23: Battery   Connected Electrical  Power  On Hydraulic  Power  Off Heater  Compartment  Acoustic  Blanket  Removed Personnel   Required: Aircraft  Electrician 9-264 Change   2 GO TO NEXT PAGE