CABIN   AND   RAMP   DOME   WHITE   LIGHTS   STAY   ON   WHEN   CABIN   &   RAMP   LIGHTS   SWITCH   SET 9-15.8 TO   ALL   OFF
CABIN   AND   RAMP   LIGHTS   WIRING   DIAGRAM  

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  773    774    775    776    777  778  779    780    781    782    783  
TM    55-1520-240-T 9-15.9   CABIN   AND   RAMP   DOME   RED   LIGHTS   DO   NOT   COME   ON   WHEN   CABIN   &   RAMP   LIGHTS 9 - 1 5 . 9 SWITCH   SET   TO   RED   ON FAULT   ISOLATION   PROCEDURE INITIAL   SETUP Applicable  Configurations: W  i  t  h  o  u  t   Tools: Electrical   Repairer’s   Tool   Kit, NSN   5180-00-323-4915 Multimeter Materials: None Personnel   Required: Aircraft   Electrician   (2) References: TM    55-1520-240-23 Equipment   Condition: TM    55-1520-240-23: Battery    Connected Electrical  Power  Off Hydraulic   Power   Off END  OF  TASK Change  2 9 - 2 7 5