CABIN   AC   RECEPTACLE   CIRCUIT   BREAKER   WILL   NOT STAY   CLOSED   (Continued)
NO   ELECTRICAL   POWER   AT   UTILITY   DC   RECEPTACLES   ON   LEFT   SIDE   OF   AIRCRAFT   (Continued)

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  816    817    818    819    820  821  822    823    824    825    826  
TM 55-1520-240-T 9-17.6   NO   ELECTRICAL   POWER   AT   UTILITY   DC   RECEPTACLES ON   LEFT   SIDE   OF   AIRCRAFT FAULT   ISOLATION   PROCEDURE INITIAL   SETUP Applicable   Configurations: All Tools: Electrical   Repairer’s   Tool   Kit, N S N     5 1 8 0 - 0 0 - 3 2 3 - 4 9 15 Multimeter Materials: None Personnel    Required: 68F20    Aircraft    Electrician References: T M     5 5 - 1 5 2 0 - 2 4 0 - 23 Equipment   Condition: T M     5 5 - 1 5 2 0 - 2 4 0 - 2 3: Battery   Connected Electrical   Power   On Hydraulic   Power   Off 9-17.6 0145-9668-SPA GO  TO  NEXT  PAGE 9-312