NO. 1 ENGINE GAS PRODUCER TACHOMETER READING FLUCTUATES OR IS ERRATIC - TM-55-1520-240-T-2_95
NO. 2 ENGINE GAS PRODUCER TACHOMETER READING FLUCTUATES OR IS ERRATIC - TM-55-1520-240-T-2_97

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  58    59    60    61    62  63  64    65    66    67    68  
TM 55-1520-240-T 8-2.7 NO. 2 ENGINE GAS PRODUCER TACHOMETER READING FLUCTUATES OR IS ERRATIC 8-2.7 FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required: Applicable Configurations: Aircraft Electrician Without 74 References: Tools: TM 55-1520-240-23 Electrical Repairer Tool Kit, Equipment Condition: NSN 5180-00-323-4915 TM 55-1520-240-23: Multimeter Battery Connected Materials: Electrical Power Off None Hydraulic Power Off END OF TASK 8-42.2  Change 19