• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
AN/ALE-47 COUNTERMEASURES DISPENSER SYSTEM OPERATIONAL CHECK
AN/ALE-47 COUNTERMEASURES DISPENSER SYSTEM OPERATIONAL CHECK (Continued) - TM-55-1520-240-T-3_1017

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  928    929    930    931    932  933  934    935    936    937    938  
TM 55-1520-240-T Change 24    16-193 16-5.3  AN/ALE-47 COUNTERMEASURES DISPENSER SYSTEM OPERATIONAL CHECK (Continued) 16-5.3 TASK RESULT NOTE Do not install CDTs into Countermeasures Dispenser System (CMDS) dispenser assemblies before performing CDT BIT check. 1.    Set CDT MODE switch (18) to FIRE TEST. BIT begins automatically.  The following displays appear on   the CDT: All CDT indicators illuminate briefly. BIT is displayed on upper display field. “S-“ and software version number is displayed If no fault is detected PASS message is displayed. If fault is detected FAIL message is displayed, set MODE   switch to OFF and replace CDT. 2.    Set CDT DATA switch (19) to COUNT or DUAL COUNT (chaff use). 3.    Check CDT display (20) for battery message. If LOW BAT is displayed, refer to TM 341003 (Operation and Maintenance Technical Manual) accompanying CDTs. 4.    Set CDT MODE switch (18) to OFF. NOTE If erroneous expendable counts are displayed, fastening knobs may require additional tightening. 5.    Install CDTs (16) into flare dispenser assemblies (15) being tested; secure CDTs (16) by tightening two fastening knobs (17). 6.    Apply electrical power to aircraft. NOTE Proceed with AN/ALE-47 CMDS operational checkout while AN/ALQ-156 MWS is warming up. 7.    Set AN/ALQ-156 POWER switch (10) to ON; press After 10 minutes, STBY light on AN/ALQ-156 illuminates. AN/ALQ-156 PUSH FOR STANDBY switch (9) to   initiate standby mode. 8.    Set CDT MODE switch (18) to S.V. (stray voltage). TASK RESULT 9.    Press CDT RESET TEST switch (21). DC followed by AC is displayed on CDT display (20) for 4   seconds.  If stray voltage is not detected, PASS is displayed. If FAIL message is displayed, failed pin numbers will then be   displayed. Record failed pin numbers. This is an indication that stray voltage was  detected on the  dispenser breechplate   terminals.  This condition must be corrected before proceeding with the operational check.  Power down the AN/ALQ-156   MWS and remove power from aircraft.  Starting at the   dispenser pins, use multimeter to locate the source of stray voltage.  If CMDS is not the source of the stray voltage, the aircraft wiring must be checked to locate and repair the stray voltage     condition. 10.  Set CDT MODE switch (18) to OFF. WARNING Do not perform operational checkout of CMDS with payload modules installed in dispenser assemblies.  System could inadvertently dispense flares resulting in damage to aircraft or injury or death to personnel. 11.  Ensure DCALE47DCDU (12), NO. 1 SEQ (14), If DCALE47 DCDU circuit breaker is open, close it.  If it does    and NO. 2 SEQ (13) circuit breakers on EAPS not stay closed, go to Task 16-5.4. 1 PDP (11) are closed (in). 12.  Adjust DCDU (4) and Misc. Control panel (3) edge DCDU and misc. control panel edge brightness goes lighting from dim to bright and set as desired   from dim to bright as control is rotated. using LTG CTR CSL switch (1) on cockpit overhead instrument panel. 13.  Set the following switches on DCDU (4): JETTISON switch (8) – OFF (switch guard closed) MANUAL switch (6) – 1 14.  Set CDT MODE switch (18) to FIRE TEST. 15.  Set CDT DATA switch (19) to COUNT. a.    All CDT indicators illuminate briefly. b.    BIT is displayed on upper display field. c.    “S-“ and version number is displayed on CDT. d.    BIT begins automatically. e.    BIT FAIL message is displayed, press RESET TEST   button (21) on CDT; FIRE and 00 messages are          displayed. GO TO NEXT PAGE







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.