COUNTERMEASURES DISPENSER TEST SET DOES NOT INDICATE A FIRED EXPENDABLE WHEN COPILOTS FLARE DISP SWITCH IS PRESSED (Continued)
COUNTERMEASURES DISPENSER TEST SET DOES NOT INDICATE A FIRED EXPENDABLE WHEN PILOTS FLARE DISP SWITCH IS PRESSED (Continued)

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  954    955    956    957    958  959  960    961    962    963    964  
TM 55-1520-240-T Change 24           16-219      16-5.10  COUNTERMEASURES DISPENSER TEST SET DOES NOT INDICATE A FIRED EXPENDABLE WHEN PILOT’S FLARE DISP SWITCH IS PRESSED 16-5.10 WT0060 A B C D E 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 A B C D NO. 1 PDP DCDU CIRCUIT BREAKER CMDS 01 02 CH INHIBIT FL RWR OFF STBY MAN SEMI AUTO BYP 1 2 3 4 PRG MWS JMR ENT BIT MODE MANUAL DISPENSE J E T T I S O N FLARE DISP SWITCH PILOT'S CYCLIC STICK GRIP DCDU EAPS/MEAPS C/B PANEL FAULT ISOLATION PROCEDURE INITIAL SETUP Personnel Required: Avionics Mechanic Applicable Configurations: All References: TM 55-1520-240-23 Tools: Electronic Equipment Tool Kit, Equipment Conditions:   NSN 5180-00-064-5178 TM 55-1520-240-23:   Battery Connected Materials:   Electrical Power On None   Hydraulic Power Off GO TO NEXT PAGE