CHARGE INDICATOR LAMPS ON ONE OR MORE EMERGENCY EXIT LIGHTS DO NOT COME ON WHEN 17-1.5 SWITCH IS SET TO ARM (Continued) - TM-55-1520-240-T-3_1062
EMERGENCY EXIT LIGHT MAIN LAMPS COME ON WHEN SWITCH IS AT ARM - TM-55-1520-240-T-3_1064

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  973    974    975    976    977  978  979    980    981    982    983  
TM   55-1520-240-T 17-1.6 EMERGENCY EXIT LIGHT MAIN LAMPS COME ON WHEN SWITCH IS AT ARM 17-1.6 FAULT ISOLATION PROCEDURE INITIAL SETUP Applicable Configurations: All Tools: Electrical Repairer’s Tool Kit, NSN    5180-00-323-4915 Multimeter Materials: None Personnel  Required: Aircraft Electrician References: TM    55-1520-240-23 Equipment  Condition: TM   55-1520-240-23: Battery Power On Electrical Power On Hydraulic  Power  Off GO TO NEXT PAGE 17-12 Change 3