TM  55-1520-240-T 10-2.13 RH FUEL PUMP MAIN AFT CIRCUIT BREAKER WILL NOT STAY CLOSED 10-2.13 FAULT  ISOLATION  PROCEDURE INITIAL  SETUP Applicable    Configurations: All Tools: Electrical  Repairer’s  Tool  Kit, NSN   5180-00-323-4915 Multimeter Materials: None Personnel   Required: Aircraft  Electrician  (2) References: TM   55-1520-240-23 Equipment    Condition: TM   55-1520-240-23: Battery Connected Electrical  Power  On Hydraulic Power Off Side Acoustical Blanket Removed Between Sta 320  and  360 Right Aft Intertank Access Panel Open 10-64 Change 3 GO TO NEXT PAGE