PRESENT   POSITION   NOT   DISPLAYED   ON   CDU   (Continued)
CDU   DOES   NOT   DISPLAY   DOWNLOAD   WAYPTS   IN   PROCESS DURING   WAYPOINT   LOADING - TM-55-1520-240-T-3_1159

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  1062    1063    1064    1065    1066  1067  1068    1069    1070    1071    1072  
TM    55-1520-240-T 18-3.9   CDU   DOES   NOT   DISPLAY   DOWNLOAD   WAYPTS   IN   PROCESS DURING   WAYPOINT   LOADING FAULT  ISOLATION  PROCEDURES INITIAL  SETUP Applicable   Configurations: All Tools: Electrical Repairer’s Tool Kit, NSN   5180-00-323-4915 Materials: None Personnel   Required: Aircraft  Electrician References: TM  11-1520-240-23 TM  11-5841-305-12 TM   55-1520-240-23 Equipment   Condition: TM  55-1520-240-23: Battery  Connected Electrical Power On Hydraulic Power Off 1 8 - 3 . 9 GO   TO   NEXT   PAGE 18-88 Change  19