TM 55-1520-240-T 10-2.22 L FUEL PRESS CAPSULE DOES NOT GO OUT WHEN LEFT SIDE MAIN AFT FUEL PUMPS SWITCH IS SET TO ON 10-2.22 FAULT ISOLATION PROCEDURE INITIAL SETUP Equipment Condition: Applicable Configurations: TM 55-1520-240-10: All Both Engines Shut Down Tools: TM 55-1520-1520-240-23: Electrical Repairer's Tool Kit, Battery Connected NSN 5180-00-323-4915 Electrical Power On Multimeter Hydraulic Power Off Materials: Side Acoustical Blanket Removed Between Sta 320 None and 360 Personnel Required: Left Aft Intertank Access Panel Open Aircraft Electrician (2) References: TM 55-1520-240-10 TM 55-1520-240-23 GO TO NEXT PAGE 10-82  Change 23