  105    106    107    108    109  110  111    112    113    114    115  
TM 55-1520-240-T 10-2.26 LEFT SIDE AUX PRESS LIGHT COMES ON WHEN LEFT SIDE AFT AUX FUEL PUMP SWITCH IS 10-2.26 SET TO ON FAULT ISOLATION PROCEDURE INITIAL SETUP References: TM 55-1520-240-23 Applicable Configurations: All Equipment Condition: TM 55-1520-240-23: Tools Battery Connected Electrical Repairer's Tool Kit, Electrical Power On NSN 5180-00-323-4915 Hydraulic Power Off Side Acoustical Blanket Removed Between Sta Materials: 320 and 360 None Left Aft Intertank Access Panel Open Personnel Required: Aircraft Electrician (2) GO TO NEXT PAGE 10-98  Change 3