FUEL  DOES  NOT  STOP  FLOWING  WITHIN 4  SECONDS  WITH  ALL  TEST  SWITCH AT PRI OFF (cont) - TM-55-1520-240-T-3_216
FUEL  DOES  NOT  STOP  FLOWING  WITHIN  4  SECONDS WITH ALL TEST SWITCH AT SEC OFF (cont) - TM-55-1520-240-T-3_218

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  168    169    170    171    172  173  174    175    176    177    178  
TM   55-1520-240-T 10-3.13  FUEL  DOES  NOT  STOP  FLOWING  WITHIN  4  SECONDS WITH ALL TEST SWITCH AT SEC OFF 10-3.13 FAULT   ISOLATION   PROCEDURE INITIAL   STUP Applicable   Configurations: All Tools: Electrical  Repairer’s  Tool  Kit, NSN   5180-00-323-4915 Aircraft   Mechanic’s   Tool   Kit, NSN   5180-00-323-4692 Multimeter Materials: None Personnel  Required: 67U20   Medium   Helicopter   Repairer 68F20   Aircraft   Electrician References: TM   55-1520-240-23 Equipment   Condition: TM   55-1520-240-23: Battery    Connected Aircraft   Being   Refueled Hydraulic   Power   Off GO TO NEXT PAGE 10-166