AFT LCT INDICATOR NOT IN GND POSITION (Continued)
NO. 1 AFCS OFF (WITHOUT 74) OR AFCS 1 (WITH 74) CAPSULE DOES NOT GO OUT WHEN SYSTEM SELECTED (cont) - TM-55-1520-240-T-3_352

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  297    298    299    300    301  302  303    304    305    306    307  
TM 55-1520-240-T 11-3.18  NO. 1 AFCS OFF (WITHOUT 74) OR AFCS 1 (WITH 74) CAPSULE DOES NOT GO OUT WHEN SYSTEM SELECTED 11-3.18 FAULT ISOLATION PROCEDURE INITIAL SETUP References: Applicable Configurations: TM 55-1520-240-23 All TM 11-1520-240-23 Tools: Equipment Condition: Electrical Repairer Tool Kit, TM 55-1520-240-23: NSN 5180-00-323-4915 Battery Connected Multimeter Electrical Power On Materials: Hydraulic Power On None Personnel Required: Avionic Mechanic (2) GO TO NEXT PAGE 11-88  Change 23