NO. 1  ROLL  ILCA  HAS  ENGAGE  TRANSIENT  (Continued)
NO. 1 YAW ILCA HAS ENGAGE TRANSIENT (cont)

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  307    308    309    310    311  312  313    314    315    316    317  
TM   55-1520-240-T 11-3.21 NO. 1 YAW ILCA HAS ENGAGE TRANSIENT 11-3.21 FAULT  ISOLATION  PROCEDURE INITIAL  SETUP Applicable  Configurations: All Tools: Electrical Repairer’s Tool Kit, NSN  5180-00-323-4915 Multimeter Materials: None References: TM  55-1520-240-23 TM  55-4920-429-13 Equipment  Condition: TM  55-1520-240-23 Battery Connector Electrical Power On Hydraulic  Power  On TM  55-4920-429-13 AFCS Line Test Set 145G0009-1 Prepared  For  Use Personnel   Required: 35K10  Avionic  Mechanic 35K20  Avionic  Mechanic 11-96 GO TO NEXT PAGE