RADAR  ALTITUDE  HOLD  INOPERATIVE  OR  RESPONSE  ERRATIC (BAROMETRIC  ALTITUDE  HOLD  OKAY) (cont)
BAROMETRIC AND RADAR ALTITUDE HOLD INOPERATIVE OR RESPONSE ERRATIC (cont) - TM-55-1520-240-T-3_468

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  412    413    414    415    416  417  418    419    420    421    422  
TM   55-1520-240-T 11-3.63 BAROMETRIC AND RADAR ALTITUDE HOLD INOPERATIVE OR RESPONSE ERRATIC FAULT  ISOLATION  PROCEDURE INITIAL   SETUP Applicable    Configurations: All Tools: Electrical  Repairer’s  Tool  Kit, NSN 5180-00-323-4915 Multimeter Materials: None Personnel   Required: 35K10   Avionic   Mechanic 35K20   Avionic   Mechanic References: TM  55-1520-240-23 TM  55-4920-429-13 Equipment    Condition: TM  55-1520-240-23 Battery    Connected Electrical  Power  On Hydraulic  Power  On TM  55-4920-429-13 AFCS  Line  Test  Set  145G0009-1 Prepared  for  Use 11-3.63 11-188 GO TO NEXT PAGE