TM 55-1520-240-T 12-1.11  CENTER  WINDSHIELD  CONTINUES  TO  HEAT  WHEN  CTR WINDSHIELD  SWITCH  IS  AT  OFF FAULT ISOLATION PROCEDURE INITIAL   SETUP Applicable Configurations: All Tools: Electrical   Repairer’s   Tool   Kit, N S N     5 1 8 0 - 0 0 - 3 2 3 - 4 9 15 Multimeter Materials: None Personnel Required: 68F20   Aircraft   Electrician References: T M     5 5 - 1 5 2 0 - 2 4 0 - 2 3 Equipment Condition: T M    5 5 - 1 5 2 0 - 2 4 0 - 2 3: Battery   Connected Electrical   Power   On Hydraulic   Power   Off Nose   Dynamic   Absorber   Removed 12-1.11 12-20 END OF TASK