FUEL  XFEED  CONT  CIRCUIT  BREAKER  DOES NOT STAY CLOSED (Continued)
ENGINE  FUEL  SHUTOFF  CIRCUIT  BREAKER  DOES NOT STAY CLOSED (Continued)

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  12    13    14    15    16  17  18    19    20    21    22  
10-12 TM   55-1520-240-T 10-1.6  ENGINE  FUEL  SHUTOFF  CIRCUIT  BREAKER  DOES NOT STAY CLOSED FAULT   ISOLATION   PROCEDURE INITIAL    SETUP Applicable  Configurations: All Tools: Electrical    Repairer’s    Tool    Kit, N S N     5 1 8 0 - 0 0 - 3 2 3 - 4 9 15 Multimeter Materials: None Personnel    Required: 68F10   Aircraft   Electrician 68F20   Aircraft   Electrician References: T M     5 5 - 1 5 2 0 - 2 4 0 - 23 Equipment   Condition: T M     5 5 - 1 5 2 0 - 2 4 0 - 2 3: Battery   Disconnected Electrical   Power   Off Hydraulic   Power   Off 10-1-6 GO TO NEXT PAGE